Aluminum Alloy Cable
Category:
Aluminum Alloy Cable
Key Words:
Aluminum Alloy Cable
Summary:
ZC-TC90(-40)-XLPE insulated PVC sheathed aluminum alloy power cable, also known as: YJHLV, YJGLHV, YJXLHV-replace copper cable YJV, ZR-YJV, VV series products.
WhatsApp:
E-mail:
Product Details
ZC-TC90 non-armored cables are made of aluminum alloy conductors with cross sections from 16 mm2 to 400 mm2. The wire core is of ASTM Class B compacted stranded type, reaching GB/T 1838.3-2001 flame retardant Class C aluminum alloy cable conductor, which fully conforms to GB3956 and also conforms to GB/T 12706.1 and IEC60502 new versions of various standards.
Composition: The conductor is aluminum alloy, the insulation material is cross-linked polyethylene insulation with a working temperature of 90 ℃, and the external is an integral black PVC protective sheath.
Product Model
Price: Under the premise of achieving the same electrical performance, the price of aluminum alloy cable is about 30% to 50% lower than that of copper core cable.
Conductor: creep resistance, high flexibility, strong extension, low rebound, stable connection.
Insulation: high temperature resistance, anti-combustion, anti-aging, strong and durable, low carbon and environmental protection.
Outer sheath: lead-free and cadmium-free PVC, can be installed in wet places, can also be directly buried or laid in cement.
Use: aluminum alloy power cable in the United States, Canada and other developed countries have been widely used.
Application areas
Suitable for 600V ~ 35kV voltage level; Suitable for dry or humid places under 90 ℃; Can be installed indoors and outdoors, can be installed vertically, can also be laid along the wall in brackets, can also be buried underground; The minimum bending radius is 7 times the outer diameter, and can also be bent at 360 degrees. Suitable for civil, commercial, industrial, school, large venues and other places.
Product Parameters
| YJHLV (TC90) 0.6/1KV single core XLPE insulated PVC sheathed aluminum alloy power cable | |||||||||
| conductor section | Conductor diameter | Insulation thickness | Sheath thickness | Cable outer diameter | Cable weight | DC resistance of Xuhui aluminum alloy conductor at 20 ℃ | Insulation resistance | Cable current carrying capacity | |
| m㎡ | ㎜ | ㎜ | ㎜ | ㎜ | kg/km | Ω/km | ≧MΩ/km | In the air (A) | Directly buried in soil (A) |
| 10 | 3.8 | 0.7 | 1.5 | 8 | 95 | 3.08 | 0.523 | 60 | 75 |
| 16 | 4.8 | 0.7 | 1.5 | 8.9 | 120 | 1.91 | 0.431 | 75 | 100 |
| 25 | 6 | 0.9 | 1.5 | 10.4 | 190 | 1.2 | 0.444 | 115 | 130 |
| 35 | 7 | 0.9 | 1.5 | 11.5 | 207 | 0.868 | 0.379 | 140 | 150 |
| 50 | 8.4 | 1 | 1.5 | 13 | 245 | 0.641 | 0.355 | 170 | 180 |
| 70 | 10 | 1.1 | 1.5 | 14 | 336 | 0.443 | 0.335 | 215 | 225 |
| 95 | 11.6 | 1.1 | 1.5 | 16.4 | 455 | 0.32 | 0.29 | 275 | 270 |
| 120 | 13 | 1.2 | 1.5 | 17.8 | 550 | 0.253 | 0.282 | 320 | 305 |
| 150 | 14.6 | 1.4 | 2 | 20.6 | 650 | 0.206 | 0.294 | 370 | 340 |
| 185 | 16.2 | 1.6 | 2 | 22.5 | 804 | 0.164 | 0.303 | 415 | 375 |
| 240 | 18.4 | 1.7 | 2 | 24.9 | 1021 | 0.125 | 0.283 | 490 | 435 |
| 300 | 20.6 | 1.8 | 2.5 | 27.3 | 1238 | 0.1 | 0.263 | 565 | 495 |
| 400 | 23.8 | 2 | 2.5 | 34.1 | 1455 | 0.0778 | 0.243 | 640 | 555 |
| YJHLV (TC90) 0.6/1KV three-core XLPE insulated PVC sheathed aluminum alloy power cable | |||||||||
| conductor section | Conductor diameter | Insulation thickness | Sheath thickness | Cable outer diameter | Cable weight | DC resistance of Xuhui aluminum alloy conductor at 20 ℃ | Insulation resistance | Cable current carrying capacity | |
| m㎡ | ㎜ | ㎜ | ㎜ | ㎜ | kg/km | Ω/km | ≧MΩ/km | In the air (A) | Directly buried in soil (A) |
| 3 x 10 | 3.8 | 0.7 | 1.5 | 14.6 | 260 | 3.08 | 0.523 | 50 | 60 |
| 3 × 16 | 4.8 | 0.7 | 1.5 | 16.5 | 340 | 1.91 | 0.431 | 65 | 80 |
| 3 × 25 | 6 | 0.9 | 2 | 20.8 | 470 | 1.2 | 0.444 | 90 | 100 |
| 3 × 35 | 7 | 0.9 | 2 | 23.2 | 600 | 0.868 | 0.379 | 110 | 120 |
| 3 x 50 | 8.4 | 1 | 2 | 26.4 | 730 | 0.641 | 0.355 | 130 | 140 |
| 3 × 70 | 10 | 1.1 | 2 | 29.9 | 970 | 0.443 | 0.335 | 1780 | 175 |
| 3 × 95 | 11.6 | 1.1 | 2 | 33.3 | 1240 | 0.32 | 0.29 | 205 | 210 |
| 3 × 120 | 13 | 1.2 | 2.5 | 37.8 | 1540 | 0.253 | 0.282 | 240 | 235 |
| 3 × 150 | 14.6 | 1.4 | 2.5 | 41.7 | 1940 | 0.206 | 0.294 | 275 | 265 |
| 3 × 185 | 16.2 | 1.6 | 2.5 | 44.6 | 2248 | 0.164 | 0.303 | 320 | 301 |
| 3 × 240 | 18.4 | 1.7 | 2.5 | 50.1 | 2723 | 0.125 | 0.283 | 385 | 355 |
| 3 × 300 | 20.6 | 1.8 | 3 | 55.6 | 3218 | 0.1 | 0.263 | 450 | 409 |
| 3 × 400 | 23.8 | 2 | 3 | 61.6 | 3693 | 0.0778 | 0.243 | 515 | 463 |
| YJHLV (TC90) 0.6/1KV (3 1) core XLPE insulated PVC sheathed aluminum alloy power cable | |||||||||
| conductor section | Conductor diameter | Insulation thickness | Sheath thickness | Cable outer diameter | Cable weight | DC resistance of Xuhui aluminum alloy conductor at 20 ℃ | Insulation resistance | Cable current carrying capacity | |
| m㎡ | ㎜ | ㎜ | ㎜ | ㎜ | kg/km | Ω/km | ≧MΩ/km | In the air (A) | Directly buried in soil (A) |
| 3 × 16 1 × 10 | 4.8 | 0.7 | 1.5 | 17.5 | 407 | 1.91 | 0.431 | 70 | 90 |
| 3 × 25 1 × 16 | 6 | 0.9 | 2 | 21.8 | 566 | 1.2 | 0.444 | 105 | 120 |
| 3 × 35 1 × 16 | 7 | 0.9 | 2 | 23.8 | 683 | 0.868 | 0.379 | 130 | 140 |
| 3 × 50 1 × 25 | 8.4 | 1 | 2 | 27.4 | 849 | 0.641 | 0.355 | 160 | 170 |
| 3 × 70 1 × 35 | 10 | 1 | 2 | 31 | 1123 | 0.443 | 0.335 | 203 | 203 |
| 3 × 95 1 × 50 | 11.6 | 1.1 | 2.5 | 35.8 | 1473 | 0.32 | 0.29 | 255 | 250 |
| 3 × 120 1 × 70 | 13 | 1.2 | 2.5 | 39.7 | 1821 | 0.253 | 0.282 | 300 | 285 |
| 3 × 150 1 × 70 | 14.6 | 1.4 | 2.5 | 42.9 | 2199 | 0.206 | 0.294 | 350 | 320 |
| 3 × 185 1 × 95 | 16.2 | 1.6 | 3 | 47.4 | 2696 | 0.164 | 0.303 | 376 | 382 |
| 3 × 240 1 × 120 | 18.4 | 1.7 | 3 | 52.7 | 3408 | 0.125 | 0.283 | 435 | 439 |
| 3 × 300 1 × 150 | 20.6 | 1.8 | 3.5 | 58 | 4401 | 0.1 | 0.263 | 484 | 489 |
| 3 × 400 1 × 185 | 23.8 | 2 | 3.5 | 63.5 | 5590 | 0.0778 | 0.243 | 555 | 561 |
| YJHLV (TC90) 0.6/1KV (3 2) core XLPE insulated PVC sheathed aluminum alloy power cable | |||||||||
| conductor section | Conductor diameter | Insulation thickness | Sheath thickness | Cable outer diameter | Cable weight | DC resistance of Xuhui aluminum alloy conductor at 20 ℃ | Insulation resistance | Cable current carrying capacity | |
| m㎡ | ㎜ | ㎜ | ㎜ | ㎜ | kg/km | Ω/km | ≧MΩ/km | In the air (A) | Directly buried in soil (A) |
| 3 × 16 2 × 10 | 4.8 | 0.7 | 1.8 | 21.68 | 510 | 1.91 | 0.431 | 72 | 85 |
| 3 × 25 2 × 16 | 6 | 0.9 | 1.8 | 25.88 | 707 | 1.2 | 0.444 | 85 | 92 |
| 3 × 35 2 × 16 | 7 | 0.9 | 1.8 | 27.88 | 821 | 0.868 | 0.379 | 102 | 110 |
| 3 × 50 2 × 25 | 8.4 | 1 | 2 | 32.08 | 1149 | 0.641 | 0.355 | 123 | 131 |
| 3 × 70 2 × 35 | 10 | 1.1 | 2.1 | 36.88 | 1513 | 0.443 | 0.335 | 152 | 159 |
| 3 × 95 2 × 50 | 11.6 | 1.1 | 2.3 | 41.76 | 1687 | 0.32 | 0.29 | 184 | 190 |
| 3 × 120 2 × 70 | 13 | 1.2 | 2.5 | 46.01 | 2106 | 0.253 | 0.282 | 213 | 216 |
| 3 × 150 2 × 70 | 14.6 | 1.4 | 2.6 | 51.32 | 2512 | 0.206 | 0.294 | 241 | 240 |
| 3 × 185 2 × 95 | 16.2 | 1.6 | 2.8 | 56.89 | 3097 | 0.164 | 0.303 | 277 | 271 |
| 3 × 240 2 × 120 | 18.4 | 1.7 | 3 | 62.89 | 4154 | 0.125 | 0.283 | 325 | 312 |
| 3 × 300 2 × 150 | 20.6 | 1.8 | 3.2 | 70.02 | 5080 | 0.1 | 0.263 | 361 | 346 |
| 3 × 400 2 × 185 | 23.8 | 2 | 3.4 | 76.87 | 6446 | 0.0778 | 0.243 | 424 | 410 |
| YJHLV (TC90) 0.6/1KV four-core XLPE insulated PVC sheathed aluminum alloy power cable | |||||||||
| conductor section | Conductor diameter | Insulation thickness | Sheath thickness | Cable outer diameter | Cable weight | DC resistance of Xuhui aluminum alloy conductor at 20 ℃ | Insulation resistance | Cable current carrying capacity | |
| m㎡ | ㎜ | ㎜ | ㎜ | ㎜ | kg/km | Ω/km | ≧MΩ/km | In the air (A) | Directly buried in soil (A) |
| 4 × 10 | 3.8 | 0.7 | 1.5 | 15.9 | 327 | 3.08 | 0.523 | 49 | 59 |
| 4 × 16 | 4.8 | 0.7 | 2 | 19.1 | 428 | 1.91 | 0.431 | 64 | 78 |
| 4 x 25 | 6 | 0.9 | 2 | 22.7 | 594 | 1.2 | 0.444 | 87 | 98 |
| 4 x 35 | 7 | 0.9 | 2 | 25.4 | 739 | 0.868 | 0.379 | 120 | 130 |
| 4 × 50 | 8.4 | 1 | 2 | 29 | 949 | 0.641 | 0.355 | 151 | 161 |
| 4 × 70 | 10 | 1.1 | 2 | 32.9 | 1271 | 0.443 | 0.335 | 183 | 192 |
| 4 × 95 | 11.6 | 1.1 | 2.5 | 37.7 | 1627 | 0.32 | 0.29 | 238 | 234 |
| 4 × 120 | 13 | 1.2 | 2.5 | 41.6 | 2016 | 0.253 | 0.282 | 285 | 276 |
| 4 x 150 | 14.6 | 1.4 | 3 | 47.6 | 2505 | 0.206 | 0.294 | 328 | 318 |
| 4 × 185 | 16.2 | 1.6 | 3 | 50.6 | 3044 | 0.164 | 0.303 | 375 | 351 |
| 4 × 240 | 18.4 | 1.7 | 3 | 56.4 | 4100 | 0.125 | 0.283 | 405 | 391 |
| 4 × 300 | 20.6 | 1.8 | 3.5 | 62.2 | 5020 | 0.1 | 0.263 | 422 | 392 |
| 4 × 400 | 23.8 | 2 | 3.5 | 68 | 6428 | 0.0778 | 0.243 | 465 | 425 |
| YJHLV (TC90) 0.6/1KV (4 1) core XLPE insulated PVC sheathed aluminum alloy power cable | |||||||||
| conductor section | Conductor diameter | Insulation thickness | Sheath thickness | Cable outer diameter | Cable weight | DC resistance of Xuhui aluminum alloy conductor at 20 ℃ | Insulation resistance | Cable current carrying capacity | |
| m㎡ | ㎜ | ㎜ | ㎜ | ㎜ | kg/km | Ω/km | ≧MΩ/km | In the air (A) | Directly buried in soil (A) |
| 4 × 16 1 × 10 | 4.8 | 0.7 | 1.5 | 17.5 | 515 | 1.91 | 0.431 | 74 | 77 |
| 4 × 25 1 × 16 | 6 | 0.9 | 2 | 21.8 | 717 | 1.2 | 0.444 | 88 | 97 |
| 4 × 35 1 × 16 | 7 | 0.9 | 2 | 23.8 | 831 | 0.868 | 0.379 | 115 | 125 |
| 4 × 50 1 × 25 | 8.4 | 1 | 2 | 27.4 | 1162 | 0.641 | 0.355 | 150 | 159 |
| 4 × 70 1 × 35 | 10 | 1.1 | 2 | 31 | 1623 | 0.443 | 0.335 | 178 | 183 |
| 4 × 95 1 × 50 | 11.6 | 1.1 | 2.5 | 25.8 | 2231 | 0.31 | 0.29 | 228 | 237 |
| 4 × 120 1 × 70 | 13 | 1.2 | 2.5 | 39.7 | 2665 | 0.253 | 0.282 | 279 | 287 |
| 4 × 150 1 × 70 | 14.6 | 1.4 | 2.5 | 42.9 | 3190 | 0.206 | 0.294 | 323 | 338 |
| 4 × 185 1 × 95 | 16.2 | 1.6 | 3 | 47.4 | 3842 | 0.164 | 0.303 | 359 | 364 |
| 4 × 240 1 × 120 | 18.4 | 1.7 | 3 | 52.7 | 5001 | 0.125 | 0.283 | 415 | 419 |
| 4 × 300 1 × 150 | 20.6 | 1.8 | 3.5 | 58 | 5679 | 0.1 | 0.263 | 461 | 466 |
| 4 × 400 1 × 185 | 23.8 | 2 | 3.5 | 63.5 | 7185 | 0.0778 | 0.243 | 529 | 535 |
Good Cable Made by Huaqiang
Good cable, copper core is the key
High purity oxygen-free copper, anti-aging, high conductivity, low loss. Super current load capacity.
Good cable, low resistance
The resistance is small and the conductivity is higher. The resistance directly affects the consumption of current in the transmission process. The smaller the resistance, the more energy-saving.
Good cable, the insulation layer should be uniform thickness
To prevent breakdown and ensure safety, Huaqiang adopts high-quality equipment to ensure the low eccentricity and uniform thickness of the cable, effectively prevent the breakdown of wires and cables, and ensure safe use of electricity.
Good cable, safety and environmental protection first
Layer by layer testing and conscience checking, Huaqiang insists on defending the quality of national seiko, does not contain lead, cadmium, hexavalent chromium, mercury and other heavy metals, does not contain brominated flame retardants, and does not produce harmful halogen gases and corrosive gases.
Enterprise style
FAQ
01
What if the project cannot be delivered due to unstable cable performance?
02
What if the cable cannot be delivered on time and the project cannot proceed as scheduled?
03
For the same project, we need to find four or five cable factories to purchase all cables. can we not purchase all cables in one stop?
04
In the test of winter and heat, the safety performance of wire and cable can stand the test?
Phone:
WhatsApp:
E-mail:
Phone:
Address:
No.1 Huaqiang Road, Jiaozhou West Industrial Park, Qingdao, Shandong Province
Address:
No.1 Huaqiang Road, Jiaozhou West Industrial Park, Qingdao, Shandong Province
Phone:
E-mail:
Copyright © 2024 Huaqiang Cable | SEO | Business License