Computer cable is a cable for electrical equipment. This cable is suitable for electronic computers and automatic instruments with high anti-interference requirements for rated voltage of 500V and below. According to the use of different environments and equipment requirements, cable insulation can be made of polyethylene, polyvinyl chloride, cross-linked polyethylene.


National Service Hotline

WhatsApp:

Technical parameters

The minimum ambient temperature for regular computer cable laying shall be 0 ℃. Maximum allowable working temperature of cable for a long time:

 

Name of insulation material Maximum allowable working temperature (℃)
PVC 70
Polyethylene 70
cross-linked polyethylene 90
Polyolefin Materials 90、105、125、150
Silicone rubber 180
Fluoroplastics 200

 

Minimum bending radius: no armored structure should not be less than 6 times the outer diameter of the cable, armored or copper tape shielding structure should not be less than 12 times the outer diameter of the cable.

After stable charging for 1min with DC 500V voltage test at 20 ℃, the insulation resistance shall meet the following requirements:

 

insulation material Minimum insulation resistance
MΩ·km
Polyethylene, cross-linked polyethylene, fluoroplastics 3000
Polyvinyl chloride, silicone rubber 25

 

There shall be no continuous connection between each pair of shields and between the pair of shields and the total shield; the cable between the wire core and the wire core and between the wire core and the shield or other metal layers shall be subject to 50Hz, AC voltage 2000V/1min or 1500V/5min without breakdown.
Polyethylene has high insulation resistance, good voltage resistance, small dielectric coefficient and small influence of dielectric loss temperature and variable frequency, which can not only meet the requirements of transmission performance, but also ensure the service life of the cable. In order to reduce the mutual crosstalk and external interference between the circuits, the cable needs to be shielded. Shielding materials include tinned or non-tinned copper wire, copper tape, copper-plastic composite tape, aluminum-plastic composite tape, etc. The metal tape is produced by winding, and the capping rate should usually not be less than 15%, but specific standards have special regulations, such as TICW/06, which stipulates that the capping rate of shielded metal tape should not be less than 25%; The metal wire braiding production method is adopted, and the braiding coverage rate should not be less than 80%, the coverage rate may not be less than 90%.
The shielding requirements of the cable are respectively adopted according to different occasions: sub-shielding (only the pair group has shielding, and each pair group has shielding), total shielding (the cable only has one layer of total shielding after the cable core is formed), and sub-shielding total shielding (including the above two structures at the same time). According to the higher requirements of users and use occasions, the total shielding structure can adopt a composite shielding method, that is, it contains two layers of shielding, which is composed of a metal tape wrapped around a metal wire braid.
Note: If the cable has a split shield structure, the shield pair should have good insulation performance. The outer side of the split shield needs to be wrapped with polyester tape or other non-hygroscopic tape.

Composition material

Computer cable belongs to the electrical equipment cable, electrical equipment cable structure and composition of the most complex materials, according to the use of temperature, the special requirements of the working environment, computer cable structure of the composition of a wide range of materials, as follows:

 

Maximum allowable working temperature (℃) Name of insulation material Sheath Material Name
70 Polyethylene, polyvinyl chloride, thermoplastic polyolefin Polyethylene, polyvinyl chloride
90 Polyvinyl chloride, cross-linked polyethylene, thermoplastic or thermosetting polyolefin Polyvinyl chloride, thermoplastic or thermosetting polyolefin
105 Polyvinyl chloride, thermosetting polyolefin material 1 Polyvinyl chloride, thermosetting polyolefin
125、150 Thermosetting polyolefin materials 1 thermosetting polyolefin
180 Silicone rubber Silicone rubber
200 Fluoroplastics Fluoroplastics
Note 1: For thermosetting polyolefin insulation above 90 ℃, irradiation is recommended for crosslinking, especially for insulation materials with flame retardant requirements.
Note 2: Except for fluoroplastics and silicone rubber, if the cost is not considered, other sheath materials can be matched and used in cables whose insulation temperature level is lower than that of itself.

Product Model

Computer cable detailed model structure size parameters
Nominal section wire diameter structure
Number of roots/line
(mm)
 
Maximum outer diameter (mm) Approximate weight (kg/km)
DJYVP DJYVP2 DJYVP3 DJYVP DJYVP2 DJYVP3
1 × 2 × 0.5 1/0.80 7.6 7.3 9.6 65 47 83
1 × 2 × 0.75 1/0.97 8.2 7.8 10 71 52 90
1 × 2 × 1.0 1/1.13 8.8 8.5 10.6 81 61 103
1 × 2 × 1.5 1/1.38 9.5 9.2 11.3 100 78 124
1 × 2 × 2.5 1/1.78 10.5 10.2 12.3 132 109 164
2 × 2 × 0.5 1/0.8 10.5 10 12.5 109 84 139
2 × 2 × 0.75 1/0.97 11.2 10.7 13.2 134 106 165
2 × 2 × 1.0 1/1.13 12.6 12.1 14.6 158 129 196
2 × 2 × 1.5 1/1.38 13.8 13.3 15.8 244 211 284
2 × 2 × 2.5 1/1.78 16.2 15.7 18.2 270 243 343
3 × 2 × 0.5 1/0.80 11 10.5 13 132 105 163
3 × 2 × 0.75 1/0.97 12.2 11.7 14.2 169 139 202
3 × 2 × 1.0 1/1.13 13.7 13.2 15.7 196 165 236
3 × 2 × 1.5 1/1.38 15 14.5 17 249 214 303
3 × 2 × 2.5 1/1.78 17.2 16.7 19.2 347 308 415
4 × 2 × 0.5 1/0.8 11.8 11.3 12.8 165 135 199
4 × 2 × 0.75 1/0.97 12.7 12.2 14.7 206 173 242
4 × 2 × 1.0 1/1.13 14.4 14 16.4 249 206 295
4 × 2 × 1.5 1/1.38 15.7 15 17.7 310 272 370
4 × 2 × 2.5 1/1.78 18.7 18.2 20.9 462 400 518
5 × 2 × 0.5 1/0.80 13 12.5 15 194 162 233
5 × 2 × 0.75 1/0.97 14 13.5 16 247 212 299
5 × 2 × 1.0 1/1.13 16 15.5 18 288 250 349
5 × 2 × 1.5 1/1.38 17.5 17 19.5 384 341 449
5 × 2 × 2.5 1/1.78 20.9 20.4 23 564 496 627
7 × 2 × 0.75 1/0.8 13.8 13.3 15.8 242 207 296
7 × 2 × 0.75 1/0.97 15.3 14.8 17.3 310 272 368
7 × 2 × 1.0 1/1.13 17.4 17 19.5 375 333 441
7 × 2 × 1.5 1/1.38 19 18.5 21.2 512 448 566
7 × 2 × 2.5 1/1.78 22.7 22.2 25 728 654 798
8 × 2 × 0.5 1/0.80 15.3 14.8 17.3 277 240 336
8 × 2 × 0.75 1/0.97 16.8 16.3 18.8 367 325 429
8 × 2 × 1.0 1/1.13 19.2 18.7 21.5 455 382 499
8 × 2 × 1.5 1/1.38 20.4 20 22.6 592 520 649
8 × 2 × 2.5 1/1.78 24.5 24 26.8 850 770 950
10 × 2 × 0.5 1/0.80 18.2 17.7 20.2 382 319 430
10 × 2 × 0.75 1/0.97 20 19.5 22 486 417 538
10 × 2 × 1.0 1/1.13 22.8 22.3 25 579 504 640
10 × 2 × 1.5 1/1.38 24.7 24.2 27 752 668 817
10 × 2 × 2.5 1/1.78 28.8 28.3 31.2 1155 1000 1210
12 × 2 × 0.5 1/0.80 18.8 18.3 21 425 360 474
12 × 2 × 0.75 1/0.97 20 20.2 22.8 545 472 597
12 × 2 × 1.0 1/1.13 23.5 23 25.8 652 574 715
12 × 2 × 1.5 1/1.38 25.4 26 27.6 850 765 920
12 × 2 × 2.5 1/1.78 30.7 30 32.8 1305 1150 1367
14 × 2 × 0.5 1/0.80 19.5 19 21.7 475 407 528
14 × 2 × 0.75 1/0.97 21.5 21 23.7 622 545 677
14 × 2 × 1.0 1/1.13 24.6 24.1 26.8 736 655 804
14 × 2 × 1.5 1/1.38 26.7 26.2 29 1030 883 1070
14 × 2 × 2.5 1/1.78 32.5 32 35 1480 1315 1544
16 × 2 × 0.5 1/0.80 21 20.5 23 538 466 594
16 × 2 × 0.75 1/0.97 23 22.5 25 694 613 752
16 × 2 × 1.0 1/1.13 26 25.5 28.4 823 738 919
16 × 2 × 1.5 1/1.38 28.5 28 31 1165 1010 1209
16 × 2 × 2.5 1/1.78 34.5 34 37 1675 1500 1743
19 × 2 × 0.5 1/0.80 22.4 22 24.4 610 535 669
19 × 2 × 0.75 1/0.97 23.7 23.2 25.7 790 706 854
19 × 2 × 1.0 1/1.13 27 26.5 29.4 854 863 1056
19 × 2 × 1.5 1/1.38 29.6 29.1 32 1350 1185 1396
19 × 2 × 2.5 1/1.78 36 35.5 38.5 1925 1740 1998
24 × 2 × 0.5 1/0.80 25.5 25 27.7 780 692 876
24 × 2 × 0.75 1/0.97 28.2 27.8 30.7 1100 940 1141
24 × 2 × 1.0 1/1.13 32.5 32 34.8 1320 1150 1378
24 × 2 × 1.5 1/1.38 35.2 34.7 37.6 1720 1910 2159
24 × 2 × 2.5 1/1.78 42.5 42 45 2465 2250 2555

Product Name

DJYPV Polyethylene insulated twisted pair copper wire braided separate shield PVC protection Electrostatic shielding required in laying room, cable trench, pipeline, etc.
computer cable cover Occasion
DJYVP Polyethylene insulated twisted pair copper wire braided total shield PVC protection Electrostatic shielding required in laying room, cable trench, pipeline, etc.
computer cable cover Occasion
DJYPVP Polyethylene insulated twisted pair copper wire braided sub-shield and total shield poly Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Vinyl chloride sheathed computer cable Occasion
DJYP2V Polyethylene insulated twisted pair copper tape separate shield PVC sheath Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Computer Cable Occasion
DJYVP2 Polyethylene insulated twisted pair copper tape total shield PVC sheath Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Computer Cable Occasion
DJYP2VP2 Polyethylene insulated twisted pair copper tape separate shielding and total shielding polychlorinated Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Ethylene sheathed computer cable Occasion
DJYP3V Polyethylene insulated twisted aluminum-plastic composite tape separate shield PVC Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Sheathed computer cable Occasion
DJYVP3 Polyethylene insulated twisted aluminum-plastic composite tape total shielding PVC Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Sheathed computer cable Occasion
DJYP3VP3 PE Insulated Pair Stranded Aluminum-Plastic Composite Tape Sub-Shielding and General Shielding Electrostatic shielding required in laying room, cable trench, pipeline, etc.
PVC sheathed computer cable Occasion
DJYPVR Polyethylene insulated twisted pair copper wire braided separate shield PVC protection Electrostatic shielding required in laying room, cable trench, pipeline, etc.
computer cable sleeve soft Occasion
DJYVPR Polyethylene insulated twisted pair copper wire braided total shield PVC protection Electrostatic shielding required in laying room, cable trench, pipeline, etc.
computer cable sleeve soft Occasion
DJYPVPR Polyethylene insulated twisted pair copper wire braided sub-shield and total shield poly Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Vinyl chloride sheathed flexible computer cable Occasion
DJYP2VR Polyethylene insulated twisted pair copper tape separate shield PVC sheath soft Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Computer Cable Occasion
DJYVP2R Polyethylene insulated twisted pair copper tape total shield PVC sheath soft Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Computer Cable Occasion
DJYP2VP2R Polyethylene insulated twisted pair copper tape sub-shielding and general shielding Polyvinyl chloride Electrostatic shielding required in laying room, cable trench, pipeline, etc.
ene sheathed flexible computer cable Occasion
DJYP3VR Polyethylene insulated twisted aluminum-plastic composite tape separate shield PVC Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Sheathed flexible computer cable Occasion
DJYVP3R Polyethylene insulated twisted aluminum-plastic composite tape total shielding PVC Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Sheathed flexible computer cable Occasion
DJYP3VP3R PE Insulated Pair Stranded Aluminum-Plastic Composite Tape Sub-Shielding and General Shielding Electrostatic shielding required in laying room, cable trench, pipeline, etc.
PVC sheathed flexible computer cable Occasion
DJYPV22 Polyethylene insulated twisted pair copper wire braided separate shield PVC protection Electrostatic shielding required in laying room, cable trench, pipeline, etc.
sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear
DJYVP22 Polyethylene insulated twisted pair copper wire braided total shield PVC protection Electrostatic shielding required in laying room, cable trench, pipeline, etc.
sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear
DJYPVP22 Polyethylene insulated twisted pair copper wire braided sub-shield and total shield poly Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Vinyl chloride sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear
DJYP2V22 Polyethylene insulated twisted pair copper tape separate shield PVC sheathed steel Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Computer cable with armor Large mechanical external force to fix the field and bear
DJYVP2-22 Polyethylene insulated twisted pair copper strip total shield PVC sheathed steel Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Computer cable with armor Large mechanical external force to fix the field and bear
DJYP2VP2-22 Polyethylene insulated twisted pair copper tape sub-shielding and general shielding Polyvinyl chloride Electrostatic shielding required in laying room, cable trench, pipeline, etc.
ene sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear
DJYP3V22 Polyethylene insulated twisted aluminum-plastic composite tape separate shield PVC Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear
DJYVP3-22 Polyethylene insulated twisted aluminum-plastic composite tape total shielding PVC Electrostatic shielding required in laying room, cable trench, pipeline, etc.
Sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear
DJYP3VP3-22 PE Insulated Pair Stranded Aluminum-Plastic Composite Tape Sub-Shielding and General Shielding Electrostatic shielding required in laying room, cable trench, pipeline, etc.
PVC sheathed steel tape armored computer cable Large mechanical external force to fix the field and bear

Conductor Type

Nominal section of conductor Number of conductors/monofilament diameter mm Number of conductors/monofilament diameter mm Number of conductors/monofilament diameter mm Conductor DC resistance Ω/km at 20 ℃ Conductor DC resistance Ω/km at 20 ℃
mm2 A B R A、B R
0.5 1/0.80 7/0.30 16/0.20 ≤ 36.0 ≤ 39.0
0.75 1/0.97 7/0.37 24/0.20 ≤ 24.5 ≤ 26.0
1 1/1.13 7/0.43 32/0.20 ≤ 18.1 ≤ 19.5
1.5 1/1.38 7/0.52 30/0.25 ≤ 12.1 ≤ 13.3
2.5 1/1.78 7/0.68 49/0.25 ≤ 7.41 ≤ 7.98

Good Cable Made by Huaqiang

01

Good cable, copper core is the key


High purity oxygen-free copper, anti-aging, high conductivity, low loss. Super current load capacity.

Look at the raw materials.
Look at production.
02

Good cable, low resistance


The resistance is small and the conductivity is higher. The resistance directly affects the consumption of current in the transmission process. The smaller the resistance, the more energy-saving.

03

Good cable, the insulation layer should be uniform thickness


To prevent breakdown and ensure safety, Huaqiang adopts high-quality equipment to ensure the low eccentricity and uniform thickness of the cable, effectively prevent the breakdown of wires and cables, and ensure safe use of electricity.

See detection
Look at inventory
04

Good cable, safety and environmental protection first


Layer by layer testing and conscience checking, Huaqiang insists on defending the quality of national seiko, does not contain lead, cadmium, hexavalent chromium, mercury and other heavy metals, does not contain brominated flame retardants, and does not produce harmful halogen gases and corrosive gases.

Enterprise style

公司外景
公司前台
实验室
实验室1
车间
车间1

FAQ

01

What if the project cannot be delivered due to unstable cable performance?


Solution: Qingdao Huaqiang Cable promises not to produce non-standard cables. Every step in the production has been repeatedly verified. The cable performance is stable. Every meter of cable can be rechecked. The cables are used by qualified suppliers of the State Grid and state-owned enterprises.

02

What if the cable cannot be delivered on time and the project cannot proceed as scheduled?


Solution: Our company has 100 production lines, professional high-level workers 24-hour shift production, the company's own logistics system, production completed immediately shipped.

03

For the same project, we need to find four or five cable factories to purchase all cables. can we not purchase all cables in one stop?


Solution: Huaqiang Cable is a cable manufacturer integrating R & D, production and sales. Its products have nine series, more than 100 models and more than 1500 specifications. It can also be customized according to your needs and provide 1-to -1 service.

04

In the test of winter and heat, the safety performance of wire and cable can stand the test?


Solution: Huaqiang cable after 17 years of research and development and production, to ensure that you choose each wire has the wear-resistant, cold-resistant performance, really let you worry-free.

Related Products

< 1 >

Get A Quote

Note: Please leave your contact information, our professionals will contact you as soon as possible!

Submit